NATURE'S GLOBAL SERVICE
Home Page
Company Profile
Showroom
Dental X-Ray Machine
Static X-Ray, Horizontal Bucky Table
Portable X-Ray Machine
Mobile X-Ray Machine
Varian CT Scan Tube
Nago X-Ray Tube
JPI Grid
Lead Goggle
Bucky Grid
Apron
Hanger
Illuminator
Tank
Xaar Print Head
Sony Medical Thermal Paper & Printer
JPI Grid
To inquire, Select Product/s & Click on
Product Code :
07
[Select]
Product Specification
JPI grids contain the purest lead to ensure superior efficiency in removing scattered radiation.
Superior quality image is achieved through the use of aluminum interspacers and lead strips, precisely milled to uniformity.
Grid strips are sealed between smooth aluminum covers and finished with enamel providing complete resistance to heat and moisture guaranteeing years of trouble free service.
JPI grids are available in:
Various sizes: Manufactured to standard film sizes of 5x7" to 14x51" grids for special size film are also available upon your request. The overall grid is one inch larger than the film size each dimension.
Various ratios: Available with ratios of 3:1 to 15:1. The ratio is the relationship between the height of the lead strips and the distance between them.
Focus Ranges: Available with standard focus ranges of Short(26"-32"), Medium(34"-44"), Long(40"-72", 48"-72" and 60"-72") and Infinity (Parallel).
Superior densities: available with Fine-line (60 pr 70 lines/inch), Micro-line (85 lines/inch), Ultra-line (103 lines/inch), Invisible-line (150 lines/inch) and Super-invisible-line (170 or 200 lines/inch)
Cleanup
Type of Grid
Positioning Latitude
Recom-mended To
Remarks
Superlative
8:1 ratio crisscross
Distance-fair & centering
120kvp
Not recommended for titled tube techniques
Superlative
15:1 ratio linear
Very slight
100kvp
Extra care required for proper alignment.
Usually used in fixed mount.
Excellent
6:1 ratio crisscross
Good
110kvp
(Or higher)
Not suitable for tilted tube techniques.
Usually used in fixed mount.
Very good
5:1 ratio crisscross
Extreme
110kvp
Tube tilt limited 5'
Very good
10:1 ratio linear
Slight
110kvp
Reasonable care required for proper alignment
Good
8:1 ratio linear
Distance-fair centering & leveline Slight
110kvp
For general stationary grid use
<< Back
CONTACT DETAILS
A-3, New Rajinder Nagar,New Delhi - 110060, India
Phone:
91-11-28742510/28741437
Fax:
91-11-28742510/28741437
Send Mail
Contact Now
Send E-mail
Call Me Free
Key Personnel
Mr. Tarun Bhateja (Proprietor)
Mobile:
+919810270997
Copyright © 2009 by NATURE'S GLOBAL SERVICE All Rights Reserved.